Hp Proliant Dl360p Gen8 Firmware Update Iso
An HP Service Pack for ProLiant (SPP) is an ISO image that contains firmware, drivers, and software packages for Linux and Windows. The components of each SPP are pretested together for stability. To upgrade the firmware on target servers to the latest HP Service Pack baseline, use an HP-provided Insight Control server provisioning OS Build Plan to deploy an SPP as described in the post-obit sections:
-
Get to
https://www.hp.com/go/spp. -
Select
>> Download
next to the
Complete ISO Image
selection.
To re-create an SPP to your Media Server
The HP-provided Build Plans that deploy SPPs require the SPP contents to be in the directory
<
File share name
>/Media/spp
on your Media Server. Each SPP version has its own folder and the folder proper name must be the SPP version. For example, if the SPP is version
2014.02.0
, the contents of the SPP should be copied to
<
File share name
>/Media/spp/2014.02.0
For a Windows Media Server:
-
Using your favorite Windows ISO mounting utility, mountain the SPP ISO onto a folder accessible from your Media Server. The binder does not accept to be on the Media Server but it must be accessible from the Media Server via a mapped network drive. You may mount the ISO on a Linux system as long as you can map a network bulldoze to it from your Media Server. -
Follow the instructions in the
HP Insight Control Server Provisioning Installation Guide
to download the HP Insight Control server provisioning Media Server setup utility and use it to re-create the SPP ISO into the appropriate folder on your Media Server.
For a Linux Media Server
-
Mountain your SPP ISO using the Linux
mount
command with the
-o loop
option. -
Nether the directory you are exporting via NFS, create the
Media/spp/<
SPP version
>
directory, where
<
SPP version
>
is the version of your SPP as described above. -
Copy the contents of the SPP to the
Media/spp/<
SPP version
>
directory.
To run the ProLiant SW – Offline Firmware Update Build Plan
You may use the HP-provided
ProLiant SW – Offline Firmware Update
Build Plan to update the firmware on target servers. It is of import to note that the offline firmware update is performed from the Linux service Bone, not production Bone, which ways the server will be rebooted into the Linux service Bone if it is not there already.
|
|
|
Note: |
|
|
|
|
NOTE: |
|
The post-obit steps must be completed earlier running the Build Program.
-
The HP Service Pack for ProLiant (SPP) must be on your Media Server (see
Process: To download an SPP
and
Process: To copy an SPP to your Media Server). -
The parameter for the
Set Media Source
step in the Build Program is preset to employ the mount betoken
/mnt/media
to mount the SPP from the Media Server specified on your
Settings
screen. If yous would like to specify a different mount point, specify the following parameter:smb://<
username
>:<countersign
>@<Media_Server_IP
>/<sharename
>/<path
>#<mount_point
>?noserverinowhere
username
,
password
,
Media_Server_IP
,
sharename
, and
path
should all be substituted with data specific to your Media Server. The
mount_point
is the mount bespeak where the file share is to be mounted on the target server.
Annotation:
If you accept a Linux Media Server, your parameter volition start with
nfs://
, not
smb://
.
-
The following parameters are bachelor for the
Update Firmware Using SPP
stride in the Build Plan:-
––spp_version
– This optional parameter specifies the SPP version to utilize. By default, the latest SPP version is used. Use this parameter to specify a detail SPP version, such as
––spp_version=2014.02.0
. The SPP folder must exist on the file share for your Media Server and the contents of the SPP must have been previously extracted to information technology. -
––hpsum_options
– This optional parameter specifies whatsoever additional arguments to the HP SUM utility used past the
Update Firmware Using SPP
Build Plan step to perform the firmware update. The syntax of this pick is:
-—hpsum_options=”<
. For a detailed description of the available HP SUM options, refer to the
option1
option2
...
optionN
>”
hp/swpackages/CLIHelp.txt
file in the SPP. -
––hpsum_logs_dump_dir
– This optional parameter specifies a directory on a file share where the naught file containing the HP SUM logs volition be written. The HP SUM log files, which incorporate the results of the firmware update for each hardware component, can be optionally saved to your Media Server or some other system equally a single zip file by specifying the
-—hpsum_logs_dump_dir=<
directory_name
>
parameter to the
Update Firmware Using SPP
Build Plan step. The
<
directory_name
>
must be a path that begins with the file share mount point followed by a directory nether that file share where the zip file containing the HP SUM log files will be copied to.For example, if you take a mounted file share under
/mnt/media
in the
Set Media Source
Build Plan step and you lot want the zip file to exist placed in the
hpsum_logs
folder under that file share, y’all would specify:
-—hpsum_logs_dump_dir=/mnt/media/hpsum_logs
as a parameter to the
Update Firmware Using SPP
Build Plan step. When the Build Plan step has completed, the zip file
/mnt/media/hpsum_logs/hpsum_logs_<
server_id
>_<
timestamp
>.nothing
will exist created. You may then view the HP SUM logs on the system that is hosting the file share. The file share you mount in the
Set Media Source
Build Program step must be writable in gild for the nil file to exist created. If the directory you lot specify does not be, information technology will be created. -
-—no_show_log
– This optional parameter disables showing the
hpsum_log.txt
contents in the job log.
-