Hp Proliant Dl360p Gen8 Firmware Update Iso

Hp Proliant Dl360p Gen8 Firmware Update Iso

Upgrade the firmware on my ProLiant server


An HP Service Pack for ProLiant (SPP) is an ISO image that contains firmware, drivers, and software packages for Linux and Windows. The components of each SPP are pretested together for stability. To upgrade the firmware on target servers to the latest HP Service Pack baseline, use an HP-provided Insight Control server provisioning OS Build Plan to deploy an SPP as described in the post-obit sections:

To download an SPP


  1. Get to
    https://www.hp.com/go/spp.


  2. Select

    Download >>
    .


  3. Select

    >> Electric current Version
    .


  4. Select

    >> Download

    next to the

    Complete ISO Image

    selection.


  5. Enter your HP Passport user ID and password.


  6. Follow the instructions to download the SPP ISO file.

To re-create an SPP to your Media Server

The HP-provided Build Plans that deploy SPPs require the SPP contents to be in the directory


<
File share name
>/Media/spp

on your Media Server. Each SPP version has its own folder and the folder proper name must be the SPP version. For example, if the SPP is version
2014.02.0, the contents of the SPP should be copied to


<
File share name
>/Media/spp/2014.02.0

on your Media Server.

For a Windows Media Server:


  1. Using your favorite Windows ISO mounting utility, mountain the SPP ISO onto a folder accessible from your Media Server. The binder does not accept to be on the Media Server but it must be accessible from the Media Server via a mapped network drive. You may mount the ISO on a Linux system as long as you can map a network bulldoze to it from your Media Server.


  2. Follow the instructions in the
    HP Insight Control Server Provisioning Installation Guide
    to download the HP Insight Control server provisioning Media Server setup utility and use it to re-create the SPP ISO into the appropriate folder on your Media Server.

Read:  How to Upgrade 2016 Equinox Radio Firmware

For a Linux Media Server


  1. Mountain your SPP ISO using the Linux
    mount
    command with the
    -o loop
    option.


  2. Nether the directory you are exporting via NFS, create the
    Media/spp/<
    SPP version
    >

    directory, where
    <
    SPP version
    >

    is the version of your SPP as described above.


  3. Copy the contents of the SPP to the
    Media/spp/<
    SPP version
    >

    directory.

To run the ProLiant SW – Offline Firmware Update Build Plan

You may use the HP-provided

ProLiant SW – Offline Firmware Update

Build Plan to update the firmware on target servers. It is of import to note that the offline firmware update is performed from the Linux service Bone, not production Bone, which ways the server will be rebooted into the Linux service Bone if it is not there already.


[NOTE: ]

Note:
Note that when performing an offline firmware update, only the firmware components are installed from the SPP; software and driver components are not installed.



[NOTE: ]

NOTE:
The

ProLiant SW – Offline Firmware Update

Build Plan will leave the server booted to the Linux service OS. If you are updating firmware on a server already provisioned with an OS and you desire your server booted back to this OS after the firmware update is consummate, perform the post-obit steps to create a Build Programme that leaves your server booted to its provisioned Bone:


  1. Salvage the HP-provided Build Plan to a new proper noun.


  2. Edit the Build Program copy.


  3. Delete the final two steps of the Build Plan:
    Boot
    and
    Wait for HP SA agent.


  4. Add a
    Reboot
    pace at the end of the Build Program.


  5. Add a
    Look for HP SA Agent
    footstep to the end of the Build Program and specify these parameters:

    • –product

    • –atLeast iii

    • –atMost 10


  6. Salvage the Build Program.




The post-obit steps must be completed earlier running the Build Program.


  1. The HP Service Pack for ProLiant (SPP) must be on your Media Server (see
    Process: To download an SPP
    and
    Process: To copy an SPP to your Media Server).


  2. The parameter for the

    Set Media Source

    step in the Build Program is preset to employ the mount betoken
    /mnt/media
    to mount the SPP from the Media Server specified on your

    Settings

    screen. If yous would like to specify a different mount point, specify the following parameter:

    smb://<
                    
                      username
                  >:<
                    
                      countersign
                  >@<
                    
                      Media_Server_IP
                  >/<
                    
                      sharename
                  >/<
                    
                      path
                  >#<
                    
                      mount_point
                  >?noserverino
                

    where

    username
    ,

    password
    ,

    Media_Server_IP
    ,

    sharename
    , and

    path

    should all be substituted with data specific to your Media Server. The

    mount_point

    is the mount bespeak where the file share is to be mounted on the target server.


    [NOTE: ]

    Annotation:
    If you accept a Linux Media Server, your parameter volition start with
    nfs://, not
    smb://.



  3. The following parameters are bachelor for the

    Update Firmware Using SPP

    stride in the Build Plan:

    • ––spp_version
      – This optional parameter specifies the SPP version to utilize. By default, the latest SPP version is used. Use this parameter to specify a detail SPP version, such as
      ––spp_version=2014.02.0. The SPP folder must exist on the file share for your Media Server and the contents of the SPP must have been previously extracted to information technology.

    • ––hpsum_options
      – This optional parameter specifies whatsoever additional arguments to the HP SUM utility used past the

      Update Firmware Using SPP

      Build Plan step to perform the firmware update. The syntax of this pick is:
      -—hpsum_options=”<
      option1


      option2

      ...

      optionN
      >”
      . For a detailed description of the available HP SUM options, refer to the
      hp/swpackages/CLIHelp.txt
      file in the SPP.

    • ––hpsum_logs_dump_dir
      – This optional parameter specifies a directory on a file share where the naught file containing the HP SUM logs volition be written. The HP SUM log files, which incorporate the results of the firmware update for each hardware component, can be optionally saved to your Media Server or some other system equally a single zip file by specifying the
      -—hpsum_logs_dump_dir=<
      directory_name
      >

      parameter to the

      Update Firmware Using SPP

      Build Plan step. The
      <
      directory_name
      >

      must be a path that begins with the file share mount point followed by a directory nether that file share where the zip file containing the HP SUM log files will be copied to.

      For example, if you take a mounted file share under
      /mnt/media
      in the

      Set Media Source

      Build Plan step and you lot want the zip file to exist placed in the
      hpsum_logs
      folder under that file share, y’all would specify:
      -—hpsum_logs_dump_dir=/mnt/media/hpsum_logs
      as a parameter to the

      Update Firmware Using SPP

      Build Plan step. When the Build Plan step has completed, the zip file
      /mnt/media/hpsum_logs/hpsum_logs_<
      server_id
      >_<
      timestamp
      >.nothing

      will exist created. You may then view the HP SUM logs on the system that is hosting the file share. The file share you mount in the

      Set Media Source

      Build Program step must be writable in gild for the nil file to exist created. If the directory you lot specify does not be, information technology will be created.

    • -—no_show_log
      – This optional parameter disables showing the
      hpsum_log.txt
      contents in the job log.

Hp Proliant Dl360p Gen8 Firmware Update Iso

You May Also Like