TS-590S
Firmware update information
Final updated : March 12, 2020
The HF/50MHz All-manner transceiver TS-590S firmware has been updated from Version 2.04 to Version two.05 every bit follows.
We are offer the firmware updating program to the TS-590S owners.
You can update the TS-590S firmware by connecting the TS-590S to the PC by using a USB cable or an RS-232C cable.

The firmware updating program is not applicative for the TS-590SG.


The TS-590S is no longer in production. The firmware updating program Ver.ii.05 is applicable for all units of the TS-590S.

Attention
Updating the firmware from Ver.1.08 (or before) to Ver.2.05 resets the transceiver automatically due to internal memory address reallocation. If you do not want to lose user data, salvage the data using the
Radio Control Plan ARCP-590 (Ver.2.02)
earlier updating the firmware and write the data back after updating the firmware.

About virtual COM port driver


A virtual COM port commuter
needs to be installed onto the PC to use the firmware updating program with a USB cablevision.

Attention:Do not connect the transceiver to a PC using a USB cablevision before installing the virtual COM port driver.

Updated items : (Version 1.08

2.00)
[Jan 29, 2015]
The post-obit features are updated.
1. Enables employ of the new Carve up-frequency function for quick split operations.
Hold down the [Carve up] key, and the “SPLIT” indicator blinks. For example, press [five] key for “5kHz Up”, or press [0], [v] keys for “5kHz Down”. (If the specified frequency is lower, [0] must exist prefixed to the frequency.)
2. Enables the XIT frequency to exist fix while pressing [TF-Fix] key when RIT is OFF in simplex fashion.
3. Enables FINE function to exist set to ON/OFF in each fashion.
four. Enables display of the 1Hz frequency digit when the FINE role is turned on below 1MHz (except in transverter style).
5. Enables the condition of FIL A/B to be set separately for VFO A/B.
6. Enables utilize of the RX Pismire in 50MHz ring. The status can be fix separately in HF and 50MHz band.
7. Enables the setting of RF output power independently in DATA mode. (RF output power in HF SSB-Information/ FM-Information, 50M SSB-Information/ FM-Information, HF AM-DATA, and 50M AM-DATA can be set independently).
eight. Enables setting of the voice message’s PROC level and MIC gain separately from the setting of usual microphone input’s PROC level and MIC gain. (The optional VGS-1 is required)
9. Enables setting the RX equalizer / TX equalizer in each mode.
x. Enables deleting CW message memories by each memory aqueduct.
11. Enables proclamation of the type of the transmission meter.(The optional VGS-1 is required)
12. Enables announcement of the DRV OUT function ON / OFF status.(The optional VGS-i is required)
xiii. Enables declaration of the RIT/XIT frequency.(The optional VGS-ane is required)
xiv. Enables reading the status of the optional VGS-1 (if installed in the TS-590S).
15. Enables back upward of the status of the AI function ON/OFF.
17. Revises the band retention [GENE] 2nd setting to 472kHz / CW.
eighteen. Enables output of the 475kHz ring (472~479kHz) bespeak from the rear panel DRV (drive output) connector as well as 135kHz band.
nineteen. Reduces the minimum volume of the beep sound, CW side tone, VGS-1 Vocalism bulletin playback and declaration.
(Please besides update both of the Radio Control Program
ARCP-590
and the Radio Host Program
ARHP-590
for functional compatibility.)
The post-obit symptoms are revised.
1. After changing the operating way, Information VOX might not work correctly.
ii. While transmitting in SSB or CW fashion, the SWR meter level might become loftier for a moment.

Applicative models/units :
The firmware updating program Ver.2.05 is applicable for all units of the TS-590S. (The TS-590S is no longer in production.)
Note : You lot tin check the firmware version of your TS-590S past pressing [Yard.IN] + Ability ON.
The firmware version appears in the center of the LCD brandish.
Read:  H96 Pro Plus Android 7.1.2 Firmware Download UPDATED


Operating Environments
1. Operating Organization (OS)
Windows®
viii.i (32-bit or 64-bit)
Windows®
ten (32-flake or 64-scrap)
Notes:

ii. Processor
Faster than the recommended CPU for each OS.
3. System Memory (RAM)
Larger than the recommended System Retentiveness for each Bone.
4. Free Hard Bulldoze Space
100 MB or more of gratis difficult drive space.
5. Runtime
Microsoft .Cyberspace Framework 3.5 (includes .NET 2.0 and 3.0).
6. Peripheral Devices

Notes:


Attention

Updating the firmware from Ver.1.08 (or before) to Ver.two.05 resets the transceiver automatically due to internal memory address reallocation. If you do not desire to lose user data, salvage the data using the
Radio Control Plan ARCP-590
earlier updating the firmware and write the data back afterwards updating the firmware.

Usage Notes
Users are prohibited to assign, rent, lease, redistribute, or resell the software.
Users are prohibited to revise, change, translate, merge, de-compile, or opposite engineer the software.
The quality and performance of the software is not warranted for the applicability of any users.

JVCKENWOOD Corporation shall not assume liability for any defects, nor warrant anything other than is expressly provided in the understanding. The selection and introduction of the products as well equally the results there from shall be upon the liability of the users.
JVCKENWOOD Corporation shall own all copyrights and other intellectual properties for the software and all manuals and documents attached to the software. The user shall be allowed to use, non to resell, the software past obtaining a license from JVCKENWOOD Corporation. While the media in which the software is stored is possessed by the user, the ownership for the software itself shall be reserved for JVCKENWOOD Corporation.

Installation:
1. Excerpt the downloaded file “TS-590_V205E.zip” into a designated binder.
In the designated folder, a folder labeled “TS-590_V205E” will be created.
2. In the folder labeled “TS-590_V205E”, the firmware updating programme “TS-590_V205_e.exe” and “TS-590_e.chm” are automatically created.

Updating:

Click to read the firmware updating process.

Uninstalling:
Delete the folder labeled “TS-590_V205E” manually using the Explorer or an alternative method.
If you lot agree with the details listed in a higher place, click the following link to download the firmware updating program.
(The latest version includes all previous updates.)
Latest update: TS-590S Firmware Update Version 2.05 (March / 2020)

TS-590_V205E.nil : ane.41MB download
Microsoft®, Windows®, and Windows logo are registered trademarks of Microsoft Corporation in the United States and other countries.
.NET Framework is a registered trademark or trademark of Microsoft Corporation in the United States and other countries.
Read:  Vizio Blu Ray Player Vbr122 Firmware Update Download

How to Check Kenwood Ts 590 Firmware

You May Also Like