Firmware Components Can the Host Upgrade Utility Be Used to Upgrade

Firmware Components Can the Host Upgrade Utility Be Used to Upgrade

Upgrade the firmware on my ProLiant server


An HP Service Pack for ProLiant (SPP) is an ISO image that contains firmware, drivers, and software packages for Linux and Windows. The components of each SPP are pretested together for stability. To upgrade the firmware on target servers to the latest HP Service Pack baseline, use an HP-provided Insight Control server provisioning OS Build Plan to deploy an SPP every bit described in the following sections:

To download an SPP


  1. Go to
    https://www.hp.com/go/spp.


  2. Select

    Download >>
    .


  3. Select

    >> Current Version
    .


  4. Select

    >> Download

    next to the

    Complete ISO Image

    option.


  5. Enter your HP Passport user ID and password.


  6. Follow the instructions to download the SPP ISO file.

To copy an SPP to your Media Server

The HP-provided Build Plans that deploy SPPs require the SPP contents to exist in the directory


<
File share proper name
>/Media/spp

on your Media Server. Each SPP version has its own folder and the folder name must be the SPP version. For example, if the SPP is version
2014.02.0, the contents of the SPP should exist copied to


<
File share proper noun
>/Media/spp/2014.02.0

on your Media Server.

For a Windows Media Server:


  1. Using your favorite Windows ISO mounting utility, mountain the SPP ISO onto a folder accessible from your Media Server. The folder does not have to be on the Media Server merely it must be attainable from the Media Server via a mapped network drive. You may mount the ISO on a Linux organisation as long as yous tin can map a network drive to it from your Media Server.


  2. Follow the instructions in the
    HP Insight Command Server Provisioning Installation Guide
    to download the HP Insight Control server provisioning Media Server setup utility and use it to copy the SPP ISO into the advisable binder on your Media Server.

Read:  What Version Firmware Does My Linksys E1200-n300 Have

For a Linux Media Server


  1. Mount your SPP ISO using the Linux
    mount
    control with the
    -o loop
    selection.


  2. Under the directory you are exporting via NFS, create the
    Media/spp/<
    SPP version
    >

    directory, where
    <
    SPP version
    >

    is the version of your SPP as described in a higher place.


  3. Copy the contents of the SPP to the
    Media/spp/<
    SPP version
    >

    directory.

To run the ProLiant SW – Offline Firmware Update Build Programme

You lot may use the HP-provided

ProLiant SW – Offline Firmware Update

Build Plan to update the firmware on target servers. Information technology is important to notation that the offline firmware update is performed from the Linux service OS, non product OS, which means the server will be rebooted into the Linux service Os if it is not there already.


[NOTE: ]

NOTE:
Note that when performing an offline firmware update, merely the firmware components are installed from the SPP; software and driver components are not installed.



[NOTE: ]

NOTE:
The

ProLiant SW – Offline Firmware Update

Build Plan volition leave the server booted to the Linux service Os. If you lot are updating firmware on a server already provisioned with an Bone and you desire your server booted back to this OS after the firmware update is complete, perform the post-obit steps to create a Build Plan that leaves your server booted to its provisioned OS:


  1. Save the HP-provided Build Plan to a new proper noun.


  2. Edit the Build Programme copy.


  3. Delete the final 2 steps of the Build Program:
    Kicking
    and
    Wait for HP SA agent.


  4. Add together a
    Reboot
    footstep at the end of the Build Plan.


  5. Add a
    Look for HP SA Agent
    step to the end of the Build Plan and specify these parameters:

    • –production

    • –atLeast three

    • –atMost x


  6. Salvage the Build Plan.




The following steps must be completed earlier running the Build Programme.


  1. The HP Service Pack for ProLiant (SPP) must exist on your Media Server (see
    Procedure: To download an SPP
    and
    Procedure: To copy an SPP to your Media Server).


  2. The parameter for the

    Set Media Source

    footstep in the Build Program is preset to use the mountain signal
    /mnt/media
    to mountain the SPP from the Media Server specified on your

    Settings

    screen. If you lot would like to specify a different mountain indicate, specify the following parameter:

    smb://<
                    
                      username
                  >:<
                    
                      password
                  >@<
                    
                      Media_Server_IP
                  >/<
                    
                      sharename
                  >/<
                    
                      path
                  >#<
                    
                      mount_point
                  >?noserverino
                

    where

    username
    ,

    password
    ,

    Media_Server_IP
    ,

    sharename
    , and

    path

    should all exist substituted with information specific to your Media Server. The

    mount_point

    is the mount point where the file share is to be mounted on the target server.


    [NOTE: ]

    NOTE:
    If y’all have a Linux Media Server, your parameter volition kickoff with
    nfs://, not
    smb://.



  3. The following parameters are bachelor for the

    Update Firmware Using SPP

    step in the Build Programme:

    • ––spp_version
      – This optional parameter specifies the SPP version to apply. By default, the latest SPP version is used. Utilise this parameter to specify a detail SPP version, such as
      ––spp_version=2014.02.0. The SPP binder must be on the file share for your Media Server and the contents of the SPP must have been previously extracted to it.

    • ––hpsum_options
      – This optional parameter specifies whatever additional arguments to the HP SUM utility used by the

      Update Firmware Using SPP

      Build Plan step to perform the firmware update. The syntax of this option is:
      -—hpsum_options=”<
      option1


      option2

      ...

      optionN
      >”
      . For a detailed clarification of the available HP SUM options, refer to the
      hp/swpackages/CLIHelp.txt
      file in the SPP.

    • ––hpsum_logs_dump_dir
      – This optional parameter specifies a directory on a file share where the naught file containing the HP SUM logs volition be written. The HP SUM log files, which contain the results of the firmware update for each hardware component, can exist optionally saved to your Media Server or another organisation as a single naught file by specifying the
      -—hpsum_logs_dump_dir=<
      directory_name
      >

      parameter to the

      Update Firmware Using SPP

      Build Plan pace. The
      <
      directory_name
      >

      must be a path that begins with the file share mount point followed by a directory nether that file share where the zip file containing the HP SUM log files volition be copied to.

      For case, if you have a mounted file share under
      /mnt/media
      in the

      Set Media Source

      Build Program footstep and yous want the zip file to exist placed in the
      hpsum_logs
      folder nether that file share, you would specify:
      -—hpsum_logs_dump_dir=/mnt/media/hpsum_logs
      as a parameter to the

      Update Firmware Using SPP

      Build Programme pace. When the Build Programme footstep has completed, the zip file
      /mnt/media/hpsum_logs/hpsum_logs_<
      server_id
      >_<
      timestamp
      >.zip

      volition exist created. You may then view the HP SUM logs on the system that is hosting the file share. The file share you mount in the

      Set Media Source

      Build Plan step must be writable in order for the aught file to be created. If the directory you specify does not exist, it will be created.

    • -—no_show_log
      – This optional parameter disables showing the
      hpsum_log.txt
      contents in the job log.

Firmware Components Can the Host Upgrade Utility Be Used to Upgrade

Check Also

How to Update Firmware on a Samsung Hd204ui

How to Update Firmware on a Samsung Hd204ui

How to Update Firmware on a Samsung Hd204ui #i What the heck…I just got a …